Как устранить неполадки моего RAID-массива?

8

Я только что зарегистрировался в своем массиве RAID этим утром и получил:

$ cat /proc/mdstat
Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] 
md1 : active raid1 sdc7[0]
      238340224 blocks [2/1] [U_]

md0 : active raid1 sdc6[0]
      244139648 blocks [2/1] [U_]

md127 : active raid1 sdc3[0]
      390628416 blocks [2/1] [U_]

unused devices: <none>
$

Что, я полагаю, означает, что один диск моего массива (ов) мертв, это правда?

Как мне сделать правильное устранение неполадок в будущем? Моя /etc/mdadm/mdadm.confвыглядит так:

$ cat /etc/mdadm/mdadm.conf
# mdadm.conf
#
# Please refer to mdadm.conf(5) for information about this file.
#

# by default (built-in), scan all partitions (/proc/partitions) and all
# containers for MD superblocks. alternatively, specify devices to scan, using
# wildcards if desired.
#DEVICE partitions containers

# auto-create devices with Debian standard permissions
CREATE owner=root group=disk mode=0660 auto=yes

# automatically tag new arrays as belonging to the local system
HOMEHOST <system>

# instruct the monitoring daemon where to send mail alerts
MAILADDR root

# definitions of existing MD arrays
ARRAY /dev/md127 UUID=124cd4a5:2965955f:cd707cc0:bc3f8165
ARRAY /dev/md0 UUID=91e560f1:4e51d8eb:cd707cc0:bc3f8165
ARRAY /dev/md1 UUID=0abe503f:401d8d09:cd707cc0:bc3f8165

Как узнать, какой физический диск сломан и нуждается в замене?

Спасибо

EDIT1

# mdadm --detail /dev/md0
/dev/md0:
        Version : 0.90
  Creation Time : Tue Sep  1 19:15:33 2009
     Raid Level : raid1
     Array Size : 244139648 (232.83 GiB 250.00 GB)
  Used Dev Size : 244139648 (232.83 GiB 250.00 GB)
   Raid Devices : 2
  Total Devices : 1
Preferred Minor : 0
    Persistence : Superblock is persistent

    Update Time : Mon Sep 21 07:11:24 2015
          State : clean, degraded 
 Active Devices : 1
Working Devices : 1
 Failed Devices : 0
  Spare Devices : 0

           UUID : 91e560f1:4e51d8eb:cd707cc0:bc3f8165
         Events : 0.76017

    Number   Major   Minor   RaidDevice State
       0       8       38        0      active sync   /dev/sdc6
       1       0        0        1      removed
root@regDesktopHome:~# 

С чего бы это говорить Failed Devices : 0?

EDIT2
Открытие Gparted, я могу посмотреть на оба, /dev/sdbи /dev/sdcкоторые были моими двумя RAIDдрайверами. Тем не менее, mdadm считает /dev.sdb, что по какой-то причине был удален ... это странно. Я попытался смонтировать раздел на `` / dev / sdb` и получил следующее

$sudo mount /dev/sdb7 test
[sudo] password for ron: 
mount: unknown filesystem type 'linux_raid_member'

который выглядит все правильно. Как вернуть мой RAID-массив в порядок?

РЕДАКТИРОВАТЬ 3

Я побежал, smartctl -a /dev/sdcи smartctl -a /dev/sdbя также сделал, badblocks /dev/sdcи, badblocks /dev/sdbхотя sdcкажется, на 100% чистым, sdbвернул некоторые плохие блоки:

# badblocks /dev/sdb
16130668
16130669
16130670
16130671

Может ли это быть причиной ошибки, которую я вижу? Любой способ исправить / игнорировать эти плохие блоки или я должен заменить диск вместо этого?

РЕДАКТИРОВАТЬ 4

# smartctl --all /dev/sdb
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-62-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.12
Device Model:     ST31000528AS
Serial Number:    6VP0308B
LU WWN Device Id: 5 000c50 013d3ae45
Firmware Version: CC34
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Sat Sep 26 11:35:02 2015 PDT

==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/213891en

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  600) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 195) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   099   006    Pre-fail  Always       -       78420742
  3 Spin_Up_Time            0x0003   095   095   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   099   099   020    Old_age   Always       -       1240
  5 Reallocated_Sector_Ct   0x0033   099   099   036    Pre-fail  Always       -       60
  7 Seek_Error_Rate         0x000f   082   060   030    Pre-fail  Always       -       199357441
  9 Power_On_Hours          0x0032   052   052   000    Old_age   Always       -       42401
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   037   020    Old_age   Always       -       1240
183 Runtime_Bad_Block       0x0000   098   098   000    Old_age   Offline      -       2
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   094   094   000    Old_age   Always       -       6
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   050   050   000    Old_age   Always       -       50
190 Airflow_Temperature_Cel 0x0022   062   046   045    Old_age   Always       -       38 (Min/Max 30/38)
194 Temperature_Celsius     0x0022   038   054   000    Old_age   Always       -       38 (0 17 0 0 0)
195 Hardware_ECC_Recovered  0x001a   030   012   000    Old_age   Always       -       78420742
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       1
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       73332271657814
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       2822963046
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       2361465529

SMART Error Log Version: 1
ATA Error Count: 6 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 6 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:28.967  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:28.941  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:28.940  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:28.928  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:28.901  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 5 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:26.095  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:26.069  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:26.068  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:26.055  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:26.029  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 4 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:23.222  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:23.195  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:23.194  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:23.182  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:23.137  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 3 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:20.351  READ FPDMA QUEUED
  60 00 80 e8 44 ec 41 00      09:26:20.350  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:20.324  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:20.323  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:20.311  SET FEATURES [Set transfer mode]

Error 2 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 80 e8 44 ec 41 00      09:26:17.478  READ FPDMA QUEUED
  60 00 40 a8 44 ec 41 00      09:26:17.478  READ FPDMA QUEUED
  60 00 20 88 44 ec 41 00      09:26:17.476  READ FPDMA QUEUED
  60 00 08 80 44 ec 41 00      09:26:17.453  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:17.427  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

# 

РЕДАКТИРОВАТЬ 5

Я понял, что после отключения /dev/sdb, предыдущий /dev/sdcсейчас /dev/sdb. Я подтвердил, smartctl -a /dev/sdbчто серийный номер изменился после загрузки с отключенным поврежденным диском. Мне не повезло, и на диск не распространяется гарантия , поэтому я приобрету себе новый запасной диск.

stdcerr
источник
К вашему сведению: вы должны увидеть [UU] для здорового зеркала, а не [U_]. Как вы и думали, это означает, что одно из ваших зеркал отсутствует. Предложение @ Halfgaar лучше всего.
Тим С.
Re edit 6, вы сделали то, mdadm --manage ... --add ...что предложил Halfgaar?
MadHatter
2
Одной из ключевых особенностей сайтов Stack Exchange является то, что они не являются форумами и не имеют веток. Вы задали вопрос, на который был дан ответ. Если у вас есть больше (связанных) вопросов, вы должны задавать их как новые вопросы и, если применимо, ссылаться на оригинал. Прежде чем сделать это, вы можете поискать на сайте.
user9517

Ответы:

11

Видя, как вы не видите сломанный диск (помеченный F) в выводе cat /proc/mdstat, вы загрузили сервер, так как массив был поврежден.

Вы можете получить информацию с mdadm --detail /dev/md0. Это, вероятно, скажет вам, какой другой диск должен быть в нем.

Чтобы ответить на ваши изменения:

Я бы проанализировал в /dev/sdbпервую очередь. Используйте smartctl -aдля проверки (особенно) перераспределенного количества секторов и журнала ошибок. Сделайте самопроверку с smartctl -t long /dev/sdb. Использование badblocksи т. Д.

Затем:

  • Если вы замените /dev/sdb, скопируйте таблицу разделов из /dev/sdc. Если они не GPT, вы можете использовать sfdisk -d /dev/sdc | sfdisk /dev/sdb. Или, если они GPT, вы можете использовать gdiskдля сохранения таблицы разделов в файл, а затем загрузить его. Он скрыт под расширенными функциями.
  • Что-то общее, чтобы рассмотреть: если ваш (новый) диск имеет 4k секторов, убедитесь, что разделы выровнены по 4k .
  • Если вы собираетесь повторно добавить свой существующий /dev/sdb, вы можете запустить mdadm --zero-superblockна всех существующих разделах.
  • Тогда вы можете mdadm --manage /dev/md0 --add /dev/sdb6и то же самое для md1иsdb7

Излишне говорить, что некоторые команды стирают ваши данные, если вы перепутали свои диски. Так что будь уверен, что есть sdcи sdb...

Редактировать: о плохих блоках: Если какой-либо инструмент уровня программного обеспечения видит плохие блоки, диск отключается. Обычно диски скрывают их, перераспределяя их при записи. Google для «перераспределения сектора жесткого диска». Ваш smartctl -aвывод должен показывать перераспределенные сектора для sdb. Так что да, ваш sdbбыл выгнан из массива, и вам нужно заменить его.

Редактировать: о smartctl -aвыходе. Там есть две вещи, которые имеют первостепенное значение:

  • Это показывает 60 перераспределенных секторов. Даже если нормализованное значение по-прежнему равно 99 и официально будет «плохим», если оно достигнет 36 (оно ведет обратный отсчет), вы не должны доверять дискам, которые начинают перестраивать сектора. Поэтому, особенно, если это значение начинает меняться, необработанное значение очень важно. Вы даже можете настроить, smartdчтобы контролировать это для вас.
  • Журнал ошибок показывает записи в возрасте 42372 часов. Вы можете сказать, что это было недавно, из-за параметра 9 (в вашем случае) Power on hours,. Существуют безобидные вещи, которые могут вызвать записи в журнале ошибок SMART, например, неправильные команды ATA, но в этом случае, поскольку у вас поврежденный массив, вероятно, они связаны.

Что касается определения, какой диск находится в вашей системе; например, делать dmesg |grep -i sdbпоможет. Вероятно, у вас в системе три диска, и sdbэто тот диск, который установлен на вашем втором контроллере SATA, который может иметь имя 1 или 2, в зависимости от того, на нуле он или один.

Поскольку вы, вероятно, загружаетесь с sda, вы можете просто заменить sdbи выполнить операции, которые я описал выше. Если ваш загрузочный диск сломан, вы надеетесь, что у вас есть:

  • Установил grub и на другие диски.
  • Есть сервер, который может загружаться с другого диска.

На днях с сервером Dell он не хотел начинать с того sdbмомента, когда на нем было пустое sdaместо. Это потребовало некоторого убеждения и импровизации.

Иногда вам нужно перевести имена как ata1.01реальные имена устройств. Например, при сбое дисков выдается сообщение об ошибке в ядре: «Исключение ATA на ata1.01» или слова на этот счет. Прочитайте этот ответ для этого. (Я настроил нашу центральную систему ведения журналов, чтобы предупредить меня об этих ошибках ядра, потому что они являются надежным индикатором ожидающего сбоя диска).

Halfgaar
источник
Также добавлено EDIT2 сейчас
stdcerr
1
@cerr Я редактирую ответ, объясняющий, как анализировать ситуацию.
Halfgaar
1
@cerr Я прокомментировал твое обнаружение плохих блоков.
Halfgaar
1
@cerr Я отредактировал, чтобы лучше понять smartctlрезультаты.
Halfgaar
1
@cerr Это уже в моем ответе, про--add
Halfgaar